A history of timekeeping › Lesson 11 of 12 · 6 min read
Quartz and atomic time
In under a century, timekeeping accuracy improved by a factor of about a billion. The jump from pendulums and balances to quartz crystals and atoms changed the world's clocks, and in the process changed what a clockmaker does. This lesson follows the steps and puts numbers on them, so you can see where mechanical timekeeping sits in the sequence.
Quartz: a crystal as the pendulum
A slice of quartz crystal is piezoelectric: squeezing it produces a voltage, and applying a voltage makes it flex. Cut and mounted correctly, it vibrates at a very stable frequency, and an oscillator circuit that keeps it ringing can serve as a clock's regulator. In 1927 Warren Marrison and J. W. Horton, at Bell Laboratories, built the first quartz clock. It used a crystal driven by electricity at 50,000 cycles a second; a frequency divider brought that down to a rate that drove a synchronous motor. Marrison described the development in a paper of 1948 in the Bell System Technical Journal, which is the primary source for these dates and figures (not checked in full text here).
The quartz wristwatch
Getting a quartz clock from a room-sized laboratory instrument into a wristwatch needed miniature crystals and low-power electronics. Seiko unveiled the Quartz Astron in Tokyo on 25 December 1969. It used a quartz oscillator at 8,192 hertz, and was claimed to be accurate to plus or minus five seconds a month (about a minute a year). The IEEE Milestone record says that 100 18-carat gold watches were sold within a week of its introduction. Cheap quartz watches followed during the 1970s and brought great difficulty for traditional watch industries.
| Date | Event |
|---|---|
| 1927 | First quartz clock (Marrison and Horton, Bell Labs), crystal at 50,000 Hz |
| 25 December 1969 | Seiko Quartz Astron, crystal at 8,192 Hz, claimed ±5 s a month |
Why quartz works: numbers
Counting is easier than swinging. A crystal at 32,768 hertz (2 to the power 15, a common choice for watches and clocks) is divided by 15 successive halvings to give one pulse a second. The Astron's 8,192 Hz is 2 to the power 13.
Worked example. A cheap crystal with a frequency error of 20 parts per million runs fast or slow by 20 × 10⁻⁶ × 86,400 s ≈ 1.7 seconds a day, about 52 seconds a month. A tuning-fork crystal also varies with temperature, in a parabolic curve about a turnover point of roughly 25 °C. At a commonly quoted coefficient of about −0.034 ppm per square degree (an approximate figure that varies with the crystal), 20 °C away from turnover it loses 0.034 × 400 ≈ 14 ppm, which is about 1.2 seconds a day. Mechanical regulators, in contrast, must fight friction, gravity and temperature every second.
Atomic clocks
The idea of using atoms as clocks was proposed as early as 1879 by Lord Kelvin and a colleague. An atom of a given element has energy levels that are identical for every atom of that element, and the frequency of radiation absorbed or emitted in a transition between them is a natural constant. The history in brief:
| Date | Step |
|---|---|
| 1940 | Isidor Rabi measures caesium's resonance at about 9.19 billion cycles a second |
| 1948 to 1949 | Harold Lyons's team at the National Bureau of Standards in the United States builds an ammonia-based atomic clock; it was no more accurate than existing clocks |
| May 1955 | Louis Essen (working with J. V. L. Parry) at the National Physical Laboratory unveils a caesium clock that NIST describes as the first atomic clock stable enough to serve as a time standard |
| 1958 | Essen and William Markowitz publish the frequency of the caesium transition: 9,192,631,770 cycles a second, with an uncertainty of about 20 parts per billion |
| 1967 | The General Conference on Weights and Measures redefines the second using Essen's caesium measurement |
The definition of the second
Since 1967 the second has been defined as the duration of 9,192,631,770 periods of the radiation corresponding to the transition between the two hyperfine levels of the ground state of the caesium-133 atom. It replaced a definition based on the Earth's rotation, which was found to vary: Shortt clocks and quartz clocks showed it. The number of caesium cycles in one day is 9,192,631,770 × 86,400 ≈ 7.9 × 10¹⁴. A clock that counts them with a relative error of one part in 10¹⁵ is wrong by 86,400 × 10⁻¹⁵ ≈ 9 × 10⁻¹¹ seconds a day, about 90 picoseconds.
Fountains and optical clocks
In the 1980s Bill Phillips and others used lasers to slow and cool caesium atoms (Phillips shared the 1997 Nobel Prize in Physics for this work with Steven Chu and Claude Cohen-Tannoudji), which made fountain clocks possible. NIST-F1, a caesium fountain clock, began operating in 1999, accurate to within about one second in 20 million years. Optical clocks use light rather than microwaves: light oscillates at roughly 10¹⁵ hertz, about 100,000 times faster than the 9.2 GHz of caesium. An optical clock has a narrow transition in an atom or ion (for neutral strontium, a transition at 698 nanometres with a width of about a thousandth of a hertz), a very stable laser to probe it and a femtosecond frequency comb to count the laser's oscillations. In 2006 NIST reported a single-mercury-ion optical clock at least five times more precise than NIST-F1, which it said was at a level superior to the best caesium clocks. In 2024 NIST and JILA reported a strontium optical lattice clock with a systematic uncertainty of 8 × 10⁻¹⁹, and NIST says optical clocks of this class are expected to lose only about one second in 30 billion years. Metrologists expect to redefine the second using optical clocks in the coming decades.
Putting the numbers side by side
| Timekeeper | Typical error | Fractional error |
|---|---|---|
| Verge and foliot clock | about 15 minutes a day (conventional figure) | about 1 × 10⁻² |
| Huygens pendulum clock (1656) | about 15 seconds a day | about 2 × 10⁻⁴ |
| Shortt free pendulum clock | about 1 second a year (widely quoted, not verified) | about 3 × 10⁻⁸ |
| Seiko Astron (claimed) | ±5 seconds a month | about 2 × 10⁻⁶ |
| NIST-F1 caesium fountain (1999) | 1 second in 20 million years | about 2 × 10⁻¹⁵ |
| JILA strontium lattice clock (2024) | systematic uncertainty 8 × 10⁻¹⁹ (about 1 second in 30 billion years expected) | about 1 × 10⁻¹⁸ |
Sources
- NIST, A brief history of atomic time (Kelvin 1879, Rabi 1940, NBS 1948-49, Essen 1955, 1958 measurement, 1967 redefinition, NIST-F1 1999).
- National Physical Laboratory, Louis Essen.
- IEEE (Engineering and Technology History Wiki), Milestone: Electronic Quartz Wristwatch, 1969 (Seiko Astron).
- NIST, Mercury atomic clock keeps time with record accuracy (2006) and JILA strontium lattice clock news release (2024).
- Warren A. Marrison, The Evolution of the Quartz Crystal Clock, Bell System Technical Journal 27(3), July 1948 (bibliographic record checked; full text not read here).