A history of timekeeping › Lesson 9 of 12 · 8 min read
Railways, standard time and the Great Clock
For most of history, every town kept its own time, set by the Sun. A few minutes' difference between neighbouring towns mattered to nobody on foot or horseback. Railways changed that. A timetable needs one time, and once the electric telegraph could carry a signal faster than a train, one time was possible. The story of how it was agreed explains why so many Victorian public clocks carry two minute hands, and why Big Ben was built with a special escapement.
Local time and the problem of distance
The Earth turns once in 24 hours, so every 15 degrees of longitude is one hour, and one degree is four minutes of time. Places east of Greenwich see noon earlier, and places west see it later.
Worked example. Bristol lies about 2.6 degrees west of Greenwich, so its local noon comes 2.6 × 4 ≈ 10 minutes after London's. Exeter, at about 3.5 degrees west, is behind by about 14 minutes. These match the offsets found on the dual-hand "railway time" clocks that once showed local time and London time together: Exeter's second hand was 14 minutes apart and Bristol's was 10.
Britain: railway time to legal time
| Date | Event |
|---|---|
| 1833 | The Time Ball at the Royal Observatory, Greenwich, is first used as a public time signal |
| 1839 | Electric telegraph installed on a short section of the Great Western Railway |
| 1840 to 1841 | The Great Western Railway adopts London (Greenwich) time at its stations; sources differ between November 1840 and 1841 |
| 1846 to 1847 | Other railway companies follow one by one (the Midland is often given as 1846; dates for individual companies were not checked) |
| 1847 | The Railway Clearing House recommends that railways adopt Greenwich time once the Post Office permits (Science Museum Group) |
| 1852 | The Shepherd Gate Clock is installed at Greenwich, the first clock to show GMT directly to the public. Exeter adopts railway time in November (Science Museum Group); the link from Greenwich to London by telegraph for time signals also dates from the early 1850s (not checked here) |
| By 1855 | Most public clocks in Britain keep Greenwich time; the Science Museum Group estimates 98 per cent, and station clocks are set from telegraph signals |
| 2 August 1880 | The Statutes (Definition of Time) Act gives Greenwich Mean Time legal status in Great Britain |
By 1852 almost all of the United Kingdom ran on "railway" or "London" time, although the law did not recognise it for nearly thirty years. Ireland kept Dublin mean time, 25 minutes behind London, until October 1916.
How the telegraph carried time
The principle is simple. A master clock at an observatory is compared with the stars. It sends an electric pulse down a telegraph line at a fixed moment, and every receiving clock is corrected by it, either by a person or automatically. Greenwich had a time ball, a ball dropping at one o'clock, for ships and the public; the telegraph carried the same signal to inland clocks. The pulse travels in milliseconds, so the time arrives effectively without delay. This is the origin of the distributed time systems that later became "master and slave" clocks.
North America: from fifty local times to four
Before standardisation North America had well over a hundred local times, and the Library of Congress notes that the railroads were using an estimated 80 different times themselves. In October 1883 the railways' General Time Convention considered William F. Allen's plan for zones an hour apart based on the 75th, 90th, 105th and 120th meridians west of Greenwich, and the railroads changed over at noon on 18 November 1883. The government took longer: the Standard Time Act of 1918 wrote the zones into federal law.
| Zone | Reference meridian | Hours behind Greenwich |
|---|---|---|
| Eastern | 75° W | 5 |
| Central | 90° W | 6 |
| Mountain | 105° W | 7 |
| Pacific | 120° W | 8 |
Greenwich as the prime meridian, 1884
The International Meridian Conference met in Washington, D.C., in October 1884, at the request of President Chester A. Arthur. The published protocols list 24 countries present, and 25 states appear in the vote tallies. The delegates voted 22 to 1, with two abstentions, to recommend Greenwich as the initial meridian. San Domingo (now the Dominican Republic) voted against, and France and Brazil abstained. A single prime meridian for all nations was endorsed unanimously, and a universal day, a mean day beginning at midnight on the initial meridian, was also voted for (15 for, 2 against, 7 abstentions). France is commonly said to have held out against the Greenwich standard until 1911; We did not verify that date.
The Great Clock at Westminster
When the new Palace of Westminster was rebuilt after the fire of 1834, its architect Charles Barry wanted a clock tower with the best clock in the world. A dispute followed. The Queen's clockmaker Benjamin Lewis Vulliamy began a design, and other makers, including Edward John Dent, wanted to be involved. A competition was held in 1846, and the Astronomer Royal, Sir George Airy, judged it. He demanded a standard that had never been met by a turret clock: the first stroke of each hour should be accurate to within one second.
The design that satisfied him was drawn up in February 1852 by Edmund Beckett Denison, a lawyer and amateur horologist (later Lord Grimthorpe). Edward John Dent built the clock mechanism over about two years, and Frederick Dent completed the work after Edward's death. The clock was installed in April 1859 and began keeping time on 31 May 1859. Its accuracy was checked against Greenwich chronometers by telegraph.
| Item | Figure |
|---|---|
| Dial diameter | 22.5 feet (6.9 m) |
| Minute hand (copper) | 14 feet (4.3 m) |
| Hour hand (gun-metal) | 8.75 feet (2.7 m) |
| Great Bell (Big Ben) | 13.5 tonnes, cast at Whitechapel on 10 April 1858 (UK Parliament) |
| Rate adjustment | Each old penny placed on the pendulum is commonly quoted as changing the rate by 0.4 seconds a day (Parliament) |
Big Ben's first bell, cast in 1856 and about 2.5 tonnes heavier than its successor, cracked in 1857 because its hammer was too heavy; the replacement cracked in September 1859, and Airy's fix was to turn it, use a lighter hammer and cut a small square from the bell. It has been rung with the crack ever since.
Why a gravity escapement?
In a normal turret clock the train drives the escapement, so the pendulum receives a push whose size depends on the whole train: the weight, the friction of the wheels, even wind pressing on the hands and ice weighing them down. Variations in that push change the pendulum's swing and so its rate. Denison designed the clock with a double three-legged gravity escapement (a traditional account says it replaced an originally planned deadbeat escapement and remontoire, and that he never patented it; We did not verify those details).
In a gravity escapement the impulse does not come directly from the train. The train's only job is to lift small weighted arms. Each arm then falls back under its own weight onto the pendulum, giving the same push every time. The energy given to the pendulum per impulse is simply the arm's weight times the height it falls: E = m × g × h.
Worked example. A gravity arm of mass 0.5 kg that falls 5 mm gives E = 0.5 × 9.81 × 0.005 ≈ 0.025 joules. That figure does not change when the wind pushes on the hands, because the train only lifts the arm. A variation in the train changes how quickly the arm is lifted, not how much energy it gives back. (The arm mass and drop here are illustrative, not the Great Clock's own figures.)
The idea was not new, but the Great Clock's success helped make the gravity escapement the choice for high-quality turret clocks. A remontoire (a small spring or weight re-wound at intervals) works in a similar spirit, since it too separates the pendulum from variations in the train.
Sources
- UK Parliament, Constructing the most accurate clock in the world (Airy's one-second standard, Denison's design of 1852, Dent, installation in 1859, the bells).
- Royal Museums Greenwich, Greenwich Time Ball: one time for all (time ball 1833, Shepherd Gate Clock 1852).
- Science Museum Group, 'Railway Time' clock, W. Avison, York (railway time, Railway Clearing House 1847, Exeter 1852, 98 per cent by 1855).
- Network Rail, 180 years of railway time (Great Western Railway, November 1840; note that this page's statement that the 1884 conference created time zones is inaccurate and is not relied on).
- Library of Congress, Law Library, Whose time is it anyway? A brief history of standardized time zones in the United States (18 November 1883; Standard Time Act 1918).
- International Meridian Conference, Protocols of the Proceedings (Washington, 1884; Project Gutenberg transcription of the official text; vote tallies checked in the Final Act).
- Statutes (Definition of Time) Act 1880 (UK), primary text not fetched; Ireland's Dublin time until 1916 and the 1839 telegraph on the Great Western Railway are standard facts not individually sourced here. Books, not checked in full text: Derek Howse, Greenwich Time and the Discovery of the Longitude (Oxford University Press, 1980); Ian R. Bartky, One Time Fits All: The Campaigns for Global Uniformity (Stanford University Press, 2007).
Get new lessons by email