The physics and engineering of clocks › Lesson 5 of 10 · 13 min read

Friction, wear and lubrication

Friction is the main thing a clock fights against after the oscillator's air drag, and lubrication is how a repairer controls it. Oil in a clock behaves quite differently from oil in a car engine because the speeds are so low and the loads so light. Understanding why explains most of the practical rules: use tiny amounts, use the right viscosity, keep it where it is put, and never use a general-purpose oil.

Types of friction

TypeWhat it isWhere it appears in a clock
Sliding (Coulomb) frictionResistance when one surface slides on another. The friction force is Ff = μ × N, where N is the force pressing the surfaces together and μ is the coefficient of friction.Pivots in plate holes, tooth contact, pallet faces, mainspring coils rubbing in the barrel
Static versus kineticFriction needed to start sliding is usually higher than the friction while sliding.A clock that stops and will not restart has to overcome static friction; stick-slip can make a pivot jerk
Rolling frictionMuch lower than sliding. Surfaces roll rather than slide.Ideal tooth action; ball and roller bearings in a few special clocks
Fluid friction (viscous drag)Resistance of a fluid being sheared or pushed aside. Depends on speed.Air drag on the pendulum bob; oil shearing in a pivot hole

For a dry steel pivot in a brass hole μ is high, typically 0.15 to 0.3 (typical values, vary heavily with surface finish and cleanliness, so treat them as order-of-magnitude; see Stachowiak and Batchelor). A thin oil film brings it down to roughly 0.1 or lower in the boundary regime described below. I use μ = 0.1 in the worked example.

Pivot friction and its torque

A pivot of radius r carrying a total radial load F experiences a friction force μF at its surface, which acts at radius r. The friction torque is:

τf = μ × F × r     and the power lost is Pf = τf × ω

The load F is the sum of the wheel's weight and the tooth forces from its meshes. The tooth force at a mesh is the torque divided by the pitch radius of the wheel, Ftooth = τ ÷ rpitch. Reducing the pivot radius reduces the friction torque (which is why pivots on fast arbors are thin) but increases the pressure and wear, so the designer is making a compromise.

Worked example: friction in the eight-day longcase train (Lesson 2)

This uses the 6 kg weight and train from Lessons 2 and 3. The pivot sizes, loads and μ = 0.1 are assumptions typical of a clock of this type; measure your own for a real calculation.

ArborTorque (mN·m)Speed (turns/h)Pivot radius (mm)Load on both pivots (N)Friction torque μFr (mN·m)Friction as % of arbor torquePower lost (μW)
Great wheel9400.0831.564 (cord 59 N plus tooth reaction)9.61.0%1.4
Centre7811.0222.22.8%3.8
Third9.880.63.50.212.1%2.9
Escape1.3600.40.550.0221.7%2.3
Total10.5

Two lessons come out of this. First, the pivots take about 10 μW of the 137 μW supplied, about 8%. The other losses between the barrel and the escape wheel (the train was assumed to be about 80% efficient in Lesson 2, which means a loss of about 27 μW) are mostly sliding in the teeth. Second, the friction losses are spread fairly evenly down the train, each arbor wasting a similar percentage of its torque, because the load on each pivot scales with the torque at that arbor. Nothing is "unimportant". Doubling the friction of every pivot would cost about 8% more of the power budget, which a healthy clock has the margin to absorb. Doubling it in a clock that has other faults (worn teeth, a heavy pendulum) is how a marginal clock stops.

Because friction depends on μ, a pivot with no oil (μ ≈ 0.2 to 0.3) would waste two or three times as much, about 20 to 30 μW, and the bare metal surfaces would wear.

Wear

When surfaces slide, material is removed. A simple, widely used model (Archard's wear law) says that the volume worn is proportional to the load and the distance slid, and inversely proportional to the hardness of the softer material: V = K × F × s ÷ H, where K is an empirical constant that depends on the materials and lubrication and can vary by orders of magnitude. K is the unknown, so use the law for ranking, not predicting.

The sliding distance at a pivot is the circumference × the number of turns. For the train above, in a year:

ArborPivot circumference (mm)Turns per yearSliding distance per yearSurface speed (mm/s)Load × distance per pivot (N·m)
Great wheel9.47306.9 m0.0002about 220
Centre6.38,76055 m0.0017about 600
Third3.870,080264 m0.008about 460
Escape2.5525,6001.32 km0.042about 360

The loads fall as the speeds rise, so the product F × s (a measure of wear per pivot) is roughly similar along the train. This explains an observation every restorer makes: wear appears in all the pivot holes of a neglected clock, not only at the start of the train, and the holes of the centre and third arbors (high load and many turns) are often the worst. The escape arbor's thin pivot has a very high surface travel for its tiny load; it runs for a long time without noticeable wear if it has oil, but fails quickly when dry.

Why oil in a clock works differently

In an engine bearing, rotation at thousands of revolutions a minute drags oil into a wedge that physically separates the surfaces. This is hydrodynamic lubrication and it needs speed. In a clock, surface speeds are fractions of a millimetre per second (see the table), far too slow for any wedge. Clock pivots run in boundary lubrication: the oil forms a thin molecular film that adheres to the metal and stops the two surfaces touching directly. The film does not carry the load hydrodynamically; it prevents welding and abrasion. What a clock oil needs is therefore not high viscosity for load-carrying but:

(These are the general requirements for a boundary-lubricating oil in small mechanisms; the priorities vary between makers and restorers.)

Clock oil chemistry

Three families

Be careful with labels. Many "synthetic" products are blends containing mineral oil, and in North America "synthetic" has been applied to Group III oils, which are heavily refined mineral oil rather than true synthetics. Some clock oils are based on mineral oils and refined natural oils, so do not assume that every modern clock oil is a synthetic. Read the maker's description of the product.

Viscosity

Viscosity is the resistance of a fluid to shear. Two units are in common use: dynamic viscosity in centipoise (cP; 1 cP = 1 mPa·s) and kinematic viscosity in centistokes (cSt; 1 cSt = 1 mm²/s). They are related by density: dynamic viscosity = kinematic viscosity × density.

Fluid (dynamic viscosity in cP at about 20 °C; typical values, vary by product)cP
Water1
Thin synthetic clock oil for small pivots20
Honey (varies widely with water content and temperature)about 2,000 to 10,000

These are typical values and vary by product and temperature. Some restorers use automotive synthetic oils on pivots, but many prefer dedicated clock oils because an automotive oil carries an additive package designed for other purposes. As a beginner, use purpose-made clock oil until you have the experience to judge.

Viscosity changes strongly with temperature

As an illustration, take a general-purpose clock oil with a kinematic viscosity of 280 cSt at 0 °C, 95 cSt at 20 °C and 41 cSt at 40 °C and a density of 0.908 g/mL at 20 °C (typical values, vary by product; read the figures for your own oil from the maker's data). At 20 °C the dynamic viscosity is 95 × 0.908 = 86 cP. Between 0 and 40 °C the viscosity falls by a factor of nearly 7. A cold clock in an unheated hall has an oil several times thicker than in a heated room, and the extra drag is one reason clocks gain or lose time seasonally. A synthetic oil has a lower rate of change (higher "viscosity index") than a mineral oil.

Surface tension, wetting and why oil migrates

Oil on a clean brass plate does not stay put. Two surface properties decide whether a drop stays as a bead or spreads out. A liquid spreads over a solid when the surface energy of the clean solid is higher than the surface tension of the liquid plus the energy of the liquid-solid interface. Clean metals have high surface energy; lubricating oils have low surface tension (typically in the region of 20 to 35 mN/m; see de Gennes and co-workers), so oil wets clean steel and brass completely and creeps across them. The pull of this spreading is strong enough to draw oil along an arbor, up a pivot shoulder, across a plate and into the teeth. That is the usual story behind a pivot that is "dry" while a nearby pinion is wet.

Oil migrates for several connected reasons: spreading on high-energy metal surfaces, capillary action along narrow gaps, gravity, and the mechanical pumping of the moving pivot. Over-oiling makes it worse, because there is more oil than the hole can hold. Dust and old residues alter wetting too. Clock designers help by countersinking an oil sink around each pivot hole: a small conical recess in which a drop of oil forms a reservoir held by surface tension and drawn into the hole by capillarity.

Epilame

An epilame is a treatment that lowers the surface energy of a metal so oil will not spread over it. Most commercial epilames are fluoropolymers dissolved in a fluorinated solvent; the parts are dipped, leaving an invisible layer a few molecules thick that is both oil-repelling and water-repelling. The layer is bonded to the surface and keeps the lubricant in its intended area. Epilame is used chiefly in watchmaking and on the finest clock escapements. It must be applied to perfectly clean metal and is itself partly removed by cleaning and wear. Treatments of this kind use fluorinated solvents that are expensive and, in older formulations, environmentally harmful, and regulations restrict some of them. Do not epilame casually: use it where the maker's practice or the design calls for it (typically fine balance and escapement parts), and follow the supplier's instructions for cleaning and curing.

Grease and what it is for

Grease is oil held in a thickener (a soap or similar), so it stays where it is put and does not spread. It is the right choice where the contact is slow, heavily loaded and open to migration, and the wrong choice where the drag of a thick lubricant would cost power. In clocks:

What not to use

Safety. Many cleaning solvents are flammable and some are harmful to breathe or on skin. Work in good ventilation, away from flames and hot surfaces, with gloves, and dispose of used solvent and oily rags as hazardous waste. Fluorinated epilame solvents need particular care; follow the manufacturer's safety sheet.

Check your work

Common mistakes

Sources

Get new lessons by email

Free, practical clock repair lessons for beginners. No spam, unsubscribe any time.