The physics and engineering of clocks › Lesson 9 of 10 · 13 min read

Temperature, compensation and other error sources

Once a clock has been regulated at one temperature, a surprising amount of what remains is temperature. A steel-rod pendulum will drift by several seconds a day between winter and summer, and no amount of careful adjustment on the day you set it fixes that. This lesson quantifies thermal effects, shows how compensated pendulums defeat them, and puts the other error sources (air pressure, drive force, support and suspension) in proportion so you know which ones to chase.

Thermal expansion

When a solid is warmed, its length increases in proportion to the temperature rise. For a length L and a rise ΔT:

ΔL = α × L × ΔT

where α is the coefficient of linear expansion (per °C, or per K; the intervals are the same). Because it is a very small number it is usually quoted in parts per million (ppm) per °C, written × 10⁻⁶.

Materialα (ppm per °C)Notes and where sources differ
Carbon steel10.8 to 12.5 (use 11.5)Pendulum rods, springs
Brassabout 18 to 20, varies with the alloyBobs, tubes, gridiron rods
Bronze17.5 to 18
Zincabout 26 to 35; polycrystalline zinc data are discordant because of anisotropy (NBS Monograph 29)Varies with alloy, rolling and direction; zinc also creeps over time
Aluminium23
Lead29Bob filling
Invar (Fe-36Ni)about 0.9 near 20 °C (NIST data) to 1.5 (typical handbook values)Depends on heat treatment and composition; typically 0.5 to 2
Wood along the grain (pine)about 3 to 5Across the grain it is 10 to 20 times larger. Wood also swells and shrinks with humidity, which matters more than temperature
Fused quartz0.55Used in a few precision pendulum rods
Glass (soft/hard/Pyrex)9.0 / 5.9 / 4.0Jars of a mercury pendulum

Invar is a good example of a disagreement between sources. The NIST cryogenics database gives a rate near room temperature that works out at about 0.9 ppm per K, while typical handbook values run up to about 1.5. Both are correct for different samples: the expansion of Invar depends on heat treatment and exact nickel content.

What a temperature change does to a pendulum

Since T = 2π√(L/g), a fractional change ΔL ÷ L gives ΔT ÷ T = ½ ΔL ÷ L. If the whole effective length expands with coefficient α, then ΔT ÷ T = ½ α ΔT_temp, and in seconds a day:

rate change = 86,400 × ½ × α × (temperature rise) = 43,200 × α × (temperature rise) s/day    (loses when warm)

Rod materialα (ppm/°C)s/day per °COver a 14 °C seasonal swing
Steel11.50.507.0 s/day
Brass18.50.8011.2 s/day
Zinc301.318 s/day
Wood (pine, along grain)3 to 50.13 to 0.221.8 to 3.0 s/day
Invar0.9 to 1.50.04 to 0.0650.5 to 0.9 s/day
Fused quartz0.550.0240.3 s/day

The figures for steel (about 0.5 s/day per °C, so about 7 s/day over a 14 °C seasonal swing) and wood (about 2.9 s/day over 14 °C) agree with values calculated from the coefficients in the table. A winter-summer difference in a heated room is typically small, but in an unheated hall, a hall clock may see 15 °C or more. The error scales with the length of the pendulum that is affected: a steel rod is 1 m long, while the bob hangs on the rod below, and the bob's own expansion lifts its centre of mass slightly (the bob sits on a nut on the rod and expands upward from it), which partly offsets the rod by a small amount.

Compensation: the idea

Compensation arranges for some part of the pendulum to expand upwards (moving the centre of oscillation up) by exactly as much as the rod expands downwards. A pendulum can be built with a net effective length that does not change with temperature.

The gridiron pendulum

John Harrison devised the gridiron around 1726. Rods of steel and of a more expansive metal (brass or zinc) are connected in a frame so the steel rods expand downwards and the brass rods upwards. In a chain from the pivot to the bob, the steel rods act downward and the brass rods upward, so the net effective length is the sum of the steel lengths minus the sum of the brass lengths, and the net expansion is zero if:

αsteel × (total steel length) = αbrass × (total brass length)

Harrison's original used nine rods: five steel and four brass. Simpler versions with five rods (three steel and two brass or zinc) were common in later regulators.

Worked example: a nine-rod gridiron for a seconds pendulum

Use αsteel = 11.5 and αbrass = 19.3 ppm/°C (typical handbook values; they vary with the alloy, which is why a real gridiron is adjusted by trial); the ratio is 1.678. Let each steel rod have length Ls and each brass rod Lb.

The finished frame's rods are about 0.49 m (steel) and 0.37 m (brass), so the grid is much more compact than a single 1 m rod. In practice, makers needed to adjust the lengths empirically, because the mass of the gridiron shifts the centre of oscillation. The design suffers from the friction of the rods sliding in their holes (the rods adjust by jumps rather than smoothly), and zinc creeps and changes dimensions with time. Many "gridiron" pendulums on reproduction clocks are decorative and do not compensate at all.

The mercury pendulum

George Graham made the first mercury pendulum in 1721. A jar of mercury forms the bob. When the temperature rises, the steel rod expands and lowers the jar, but the mercury expands more (its volumetric coefficient is about 182 ppm per °C, about 181.7 × 10⁻⁶ at 20 °C) and the level in the jar rises, lifting the centre of mass of the mercury. A properly sized column cancels the rod's expansion.

Worked example. Treat the mercury as a fraction f = 0.8 of the pendulum's total mass, sitting in a jar of constant cross-section. If the column height is h, then on warming by one degree its centre of mass rises by ½ h β (β = 1.82 × 10⁻⁴) while the jar is lowered by α L (α = 11.5 × 10⁻⁶, L ≈ 1 m). Cancellation requires f × ½ × h × β = α L:

h = 2 α L ÷ (f β) = 2 × 11.5 × 10⁻⁶ × 1.0 ÷ (0.8 × 1.82 × 10⁻⁴) = 0.158 m

So the mercury column must be about 16 cm high, which agrees with the size of old mercury jars. The mercury takes longer to warm than the thin steel rod, so the compensation lags behind a change in temperature. This is why precision pendulums often use two jars of half the quantity (more surface area, faster response). The expansion of the glass jar and the jar's own thermal mass are ignored in this estimate; real mercury pendulums are tuned by adding or removing mercury.

Safety: mercury. Mercury vapour is the main hazard of liquid mercury. Liquid mercury evaporates at room temperature, and breathing the vapour can harm the nervous system, lungs and kidneys (UK Health Security Agency). Workplace exposure to mercury vapour is controlled in Great Britain under COSHH, with a limit set in HSE guidance EH40. Keep jars sealed, never heat mercury, never handle it with bare hands, do not use a vacuum cleaner on a spill, and treat any leak as an emergency. Seek advice from your local authority or hazardous waste service on disposal. Many jurisdictions restrict mercury-containing instruments; do not dismantle or dispose of a mercury pendulum without proper guidance, and do not post it or carry it on public transport without proper packaging and guidance.

Invar and compensating tubes

Invar, the iron-nickel alloy invented by Charles Édouard Guillaume (about 1896), has an expansion so small that it nearly eliminates the problem, though it cannot be ignored in a precision regulator. Riefler regulators with nickel-steel pendulums, introduced in the 1890s, were among the best timekeepers available before the Shortt free pendulum (Royal Museums Greenwich); the makers' claimed rates were a few hundredths of a second a day, which are claims rather than independent measurements. To cancel the residual expansion, the bob rests not directly on the rating nut but on a short tube of brass or zinc. The tube expands upwards and raises the bob by exactly the amount the Invar rod lengthens. The tube length ℓ follows from αtube × ℓ = αinvar × L:

For an Invar rod of 0.9 to 1.5 ppm/°C and a brass tube of 19 ppm/°C: ℓ = 0.9936 × (0.9 to 1.5) ÷ 19 = 47 to 78 mm. Because the Invar value is uncertain, the tube's length is adjusted by trial: run the clock at two temperatures, find the residual drift and lengthen or shorten the tube.

Wooden rods

Seasoned wood expands along its grain about a quarter or less as much as steel, so a wooden rod has a much smaller temperature effect, around 2 to 3 s/day over 14 °C. The weakness is moisture: it absorbs and releases water with the humidity. A wooden rod must be sealed with varnish or oil if it is to be stable.

Barometric pressure

A pendulum swings in air, and air has density. Two effects change the period with pressure: the bob is buoyed up (its effective weight falls) and it drags a cloud of air along with it (adding effective mass). Both slow the pendulum when the air is denser. Published figures for the barometric coefficient of a clock pendulum are of the order of 0.1 s/day per kPa (Matthys gives the detailed treatment). A rough check: with air at 1.2 kg/m³ and a brass bob (8,500 kg/m³), buoyancy alone changes the effective gravity by 1.4 × 10⁻⁴ of its value, which slows the pendulum by 6 s/day for the full atmosphere, or 0.06 s/day per kPa; the added-mass effect roughly doubles this, which is consistent with that order of magnitude.

A typical weather change of ±3 kPa (about 30 hPa, from a deep depression to high pressure) therefore moves the rate by about ±0.3 s/day. Precision observatory clocks were kept in sealed cases at constant pressure for exactly this reason (and in vacuum, air friction disappears and Q rises about a hundredfold).

Drive-force and amplitude effects

Changes in the drive change the amplitude, and amplitude changes the rate through the circular error (Lesson 6) and the escapement error (Lesson 8). Sources of drive variation include:

A 20% fall in amplitude from 2.5° to 2.0° shifts the rate by about 3.7 s/day through circular error alone, as shown in Lesson 6.

Suspension and support effects

Ranking the errors for a typical longcase

SourceTypical size of changeEffect on rate
Temperature (steel rod), 10 °C change10 °Cabout 5 s/day
Amplitude drop from 2.5° to 2.0°20% of arcabout 3.7 s/day
Escapement asymmetry (0.5° of centre) with drive change of 10%10% of driveabout 1.3 s/day
Barometric pressure, ±3 kPa6 kPa swingabout 0.7 s/day
Wooden rod instead of steel, 10 °C change10 °Cabout 1.3 to 2 s/day
Invar rod, 10 °C change10 °C0.4 to 0.65 s/day

The order matters when deciding what to fix: for a domestic clock, keeping the arc steady and the escapement even is worth far more than buying an Invar rod.

Check your work

Common mistakes

Sources