Escapements and regulation › Lesson 15 of 15 · 8 min read
Troubleshooting: why a clock stops, with a diagnosis flowchart
A stopped clock is a puzzle with a small number of possible answers. A beginner chases symptoms: oil here, a tweak there. A professional works through a short list of causes in a fixed order, because a fault found early can hide others and the order is chosen so that the cheapest and most common checks come first. The structure of that list is the same for every pendulum clock, and a modified version works for balance clocks.
The reasoning behind the order is simple. A clock keeps going when the power available at the escape wheel exceeds the power lost to friction and to the escapement's own demands, with a margin. So a clock stops when (a) the power is too low, (b) friction is too high or (c) the escapement asks too much (out of beat, bad depth, worn faces). Everything below is a way to find out which.
Step 0: Ask and observe
- When does it stop: straight after starting, after minutes, overnight, only when it strikes, only at one time each hour?
- Is the pendulum still swinging when the clock has "stopped"? If the pendulum swings but the hands do not move, the problem is not the escapement.
- Has the clock been moved, serviced or oiled recently? Moves cause out-of-beat and bent pivots; servicing introduces new errors.
- Is it level and secure? A wall clock on a flexing wall, or a case that leans, stops clocks that run perfectly on the bench.
The stop-time clue table
| Pattern | Points to |
|---|---|
| Stops within a minute or two, pendulum arc dying away | Power too low, friction too high, or poor depth or beat |
| Stops after a few hours, arc gradually falling | Marginal power, dry or dirty pivots, a weight line or cable catching |
| Runs, then stops at the same minute or hour mark each cycle | A hand catching another hand or the dial, a bent tooth, a tight spot in the train, the strike train releasing and loading the going train |
| Stops overnight, runs by day | Temperature or the case moving, lubricant stiffening, marginal power |
| Runs on the bench, stops in the case | Case not level or the pendulum touching the case or back board |
| Starts only when the pendulum is pushed hard | Escapement set deep, out of beat, or the pendulum arc too small to unlock |
| Stops whenever it strikes | Strike train load too high, strike release catching, dirt or bent lever |
The diagnosis flowchart (as a table)
Work down the steps. At each step do the test; if it passes, go to the next. If it fails, make the repair and begin again at step 1, because one repair can change the others.
| Step | Test | If it passes | If it fails |
|---|---|---|---|
| 1. Hands, dial and motion work | Remove the hands. Does the clock now run? Check that the hands clear each other, the dial and the glass. | Go to step 2 | Reset or bend hands; check hand-fit and motion work (see the trains module) |
| 2. Pendulum and suspension | Lift the pendulum off the crutch and set it swinging. It should swing smoothly and keep going for a long time (many minutes) without wobbling or catching. | Go to step 3 | Suspension spring kinked, twisted or rubbing; rod rubbing the case; bob loose; replace the spring or straighten (lesson 7) |
| 3. Beat | With the pendulum on the crutch, listen to the tick-tock, or use the visual test (lesson 7). | Go to step 4 | Adjust the crutch until even |
| 4. Crutch and fork | Check for binding, excessive play and rubbing on the rod. | Go to step 5 | Adjust the fork, polish, bend carefully |
| 5. Escapement action | With the clock in beat, move the pendulum by hand and watch each tooth drop. Equal drop each side, tooth locking safely, no tooth hitting a pallet back or climbing the impulse face (lessons 3-5, 9, 10). | Go to step 6 | Adjust depth; correct drop and lock; dress or replace pallets; replace bent teeth |
| 6. Escapement wear | Inspect pallet faces and teeth under a loupe; check anchor or pallet pivots for side shake and oval holes. | Go to step 7 | Polish, re-face, bush, repivot, then re-set depth |
| 7. Train free run | Wind the clock a little and remove the anchor (pendulum off). Keep a finger lightly on the escape arbor to slow it, with the train properly oiled, and let the train run down. It should run smoothly and evenly from start to finish with no hesitation or stop. | Go to step 8 | Find the tight or worn point: bent tooth or pinion leaf, tight pivot, burr, dirt, worn pivot hole, wheel rubbing a plate or a wheel; repair, then repeat the test |
| 8. Power | Check the weight cord or chain, the pulleys, or the mainspring. Try a slightly heavier or lighter driving force (guidance; do not leave a change in place without knowing why). | Go to step 9 | Clean and oil, replace line or chain, replace mainspring, check the barrel, ratchet and click (power module) |
| 9. Run test in the case | Level, fix and let the clock run for a week, checking the arc at full wind and near run-down. | Done | Return to step 2 and look again |
Tests in detail
The free-run train test
- Take the pendulum off and the anchor or verge out (or hold it clear) so the escape wheel is free.
- Make sure the train is oiled. Wind the weight or spring a small amount.
- Keep a finger lightly on the escape arbor to slow the train, so it does not race. This is a normal technique, not a last resort.
- Let the train turn through its whole range. Listen and feel for hesitation, ticking, grinding or an interrupted rhythm, and watch for a wheel that rocks or touches.
A tight spot that repeats once per turn of an arbor tells you which arbor it is. Count how often it recurs and match it to the train: once per turn of the escape wheel (once per 30 teeth for a 30-tooth wheel, or about once a minute in a seconds-beat train) is the escape wheel; once per revolution of a slower wheel points further up the train.
The minimum power test
Run the clock on its own weights, then try fitting a lighter weight (or, for a spring clock, partly wound) and note when it stops. A clock that stops with only a small reduction has little margin: friction is high or something is bound. A healthy clock should run with a comfortable margin below its fitted power, although how much depends on the clock, so treat the figure as guidance and compare it with similar clocks.
The arc test
Measure the pendulum's swing from rest with a scale behind the bob. Compare it with what that escapement normally needs (a few degrees for anchor and deadbeat types, and see lessons 3 and 4). A swing much smaller than usual means power is being lost; a swing much larger means too much power, or worn pallets and sloppy depth.
Observing at a stop
When the clock stops, note exactly where. Stopped with an escape tooth resting on the impulse face? The depth is shallow or the arc too small. Stopped with the pallet jammed on the tooth back? Too deep. Stopped with a tooth hanging off a pallet corner? Pallet worn, depth shallow, tooth bent. Stopped with the pendulum at one end of its swing and the crutch at the end of its travel? The beat is far out.
Wear: what to measure
| Part | Sign of wear | Effect |
|---|---|---|
| Pivot holes | Oval holes, pivots rocking in the holes, dark oil, brass dust | Wheel mesh changes, friction, depth drift; bush the hole |
| Pivots | Grooves, scoring, roughness | Friction and stopping; polish or repivot |
| Pinions | Polished ridges, cut leaves, uneven wear on the faces | Hesitation in the train; fit a new pinion or turn the leaf |
| Escape wheel teeth | Hooked tips, uneven lengths | Uneven drop; stopping at one point of the wheel |
| Pallet faces | Grooves and pits | Changes lock and impulse; polish or re-face |
| Crutch fork | Notched, polished or bent | Play and noise, rate change |
| Weight lines, chains, pulleys | Frayed cord, tight or bent links, seized pulley | Jerky or loss of power |
| Mainspring | Set (weak), broken, dirty | Low power; replace or clean |
Common mistakes in fault-finding
- Changing several things at once, then not knowing what cured it.
- Oiling the escapement to cure a stop that is really power or the train.
- Adding weight to force a worn clock to run. It will wear faster and will run less well.
- Ignoring the case: level, rubbing and a loose backboard cause many "stopping clocks".
- Testing for a few minutes only. Always run the clock for at least a day on the bench, then a week in the case.
For balance clocks
The method is the same with a platform in place of a pendulum: confirm free swing of the balance and look for a hairspring catching or a bent pivot (lesson 11); check the lever or cylinder escapement without the balance (lessons 9 and 10); free-run the train with the platform removed; then check the amplitude with a timing machine and judge it against what that clock should have.
Sources
- Clocks, caring for your treasures (Icon, the Institute of Conservation, 2006)
- Testing methods for mechanical watches (Witschi Electronic AG, 2025)
- Clock and Watch Escapement Mechanics, Mark V. Headrick, 1997 (self-published analysis hosted in the NAWCC online library; idealised drawing-and-simulation figures, not a standard or peer-reviewed)
- The Dead-Beat Escapement: History, Design, Repair, Michael Dempsey (self-published paper hosted on the NAWCC message board; typical figures only)
The fault tables describe common causes and cures from general workshop experience; they are typical practice and vary between clocks. Witschi's tolerances apply to modern watches.
Get new lessons by email
Free, practical clock repair lessons for beginners. No spam, unsubscribe any time.